Crestron DM NVX is Crestron's AV-over-IP platform for routing video, audio, USB, and control over standard gigabit Ethernet. In network terms the important point is that it is a proprietary Crestron video ecosystem built on multicast behavior, not an open cross-vendor video standard. Routing can be handled by a Crestron control system or by DM NVX Director virtual switching appliances.

Scope: DM NVX models in Crestron 8560H; media transport 4570 requires confirmation

platform · Catalog reviewed 2026-10-22

Related requirements

Review these entries for the services used in your design.

By Crestron

Video TransportProprietarylocal lancampus

Infrastructure Requirements

  1. Standard 1 GbE endpoint connectivity
  2. nonblocking switching
  3. IGMPv2 or IGMPv3 snooping plus an IGMP querier
  4. fast-leave
  5. uplink bandwidth budgeted for cumulative endpoint traffic
  6. network isolation via dedicated infrastructure or properly engineered VLAN / MPLS segmentation
  7. planned multicast address ranges
  8. QoS
  9. RSTP
  10. optional PIM-SM for large routed multicast networks
  11. optional DM NVX Director virtual switching appliances and optional Crestron control integration

Network & Physical Requirements

Port / allocationTransportConnection / signal flowFeature and requirementEvidence
554 (default)TCPNVX receiver / controller → NVX source

Profile requirement · Core

RTSP stream control

DM NVX 38x RTSP settings

Source checked 2026-09-27

Port Table, printed p. 3: Default RTSP
5004 (default)UDP

Multicast: 239.x.x.x

NVX transmitter → AES67/NVX receiver

Optional · Feature-dependent

AES67 media

DM NVX models in 8560H

5004 is configurable. Match the transmitter and receiver port and multicast group; QoS follows the DM NVX Network Design guide.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

319UDP

Multicast: 224.0.1.129–224.0.1.132

DSCP: CS7 (56) — reference default; verify model and firmware

Clock participant → NVX clock participant

Optional · AES67 / PTP clocking

PTP event timing

DM NVX models in 8560H

PTP is required when the selected AES67 clocking feature is used. Documented PTP TTL is 1; keep participants within the supported local subnet. QoS reference defaults: events CS7 (56), general messages CS6 (48). HPE Aruba Networking CX QoS for Crestron NVX/NAX Products, Tables 2 and 4: https://www.hpe.com/psnow/doc/a00140020enw . Verify deployed model/firmware markings; these are defaults, not IEEE-mandated DSCP values.

Source checked 2026-10-21

Ports and Protocols, printed pp. 3–4

8560H, March 2025

320UDP

Multicast: 224.0.1.129–224.0.1.132

DSCP: CS6 (48) — reference default; verify model and firmware

Clock participant → NVX clock participant

Optional · AES67 / PTP clocking

PTP general timing

DM NVX models in 8560H

PTP is required when the selected AES67 clocking feature is used. Documented PTP TTL is 1; keep participants within the supported local subnet. QoS reference defaults: events CS7 (56), general messages CS6 (48). HPE Aruba Networking CX QoS for Crestron NVX/NAX Products, Tables 2 and 4: https://www.hpe.com/psnow/doc/a00140020enw . Verify deployed model/firmware markings; these are defaults, not IEEE-mandated DSCP values.

Source checked 2026-10-21

Ports and Protocols, printed pp. 3–4

8560H, March 2025

80 (default)TCPBrowser → NVX device

Optional · HTTP redirect

Redirect to secure web configuration

DM NVX models in 8560H

Optional convenience redirect from port 80 to HTTPS 443.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

443 (default)TCPBrowser → NVX device

Optional · HTTPS management

Secure web configuration

DM NVX models in 8560H

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

22 (default)TCPAdmin workstation → NVX device

Optional · SSH administration

Console and SFTP

DM NVX models in 8560H

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

41794 (default)TCPNVX device → Control processor

Optional · CIP control

Crestron control connection

DM NVX models in 8560H

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

41796 (default)TCPNVX device → Control processor

Optional · Secure CIP control

Secure Crestron control connection

DM NVX models in 8560H

Select the configured secure or unencrypted control mode.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

123 (default)UDPNVX device → NTP server

Optional · NTP client

Time-of-day synchronization

DM NVX models in 8560H

Separate from media PTP timing.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

443 (default)TCPNVX device → XiO Cloud service

Optional · XiO Cloud

XiO Cloud connection

DM NVX models in 8560H

Required only for the cloud feature; verify current service destinations.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

ConfiguredTCPNVX device → Certificate OCSP responder

Optional · OCSP

Certificate status checks

DM NVX models in 8560H

Use the responder URL and port in the certificate; commonly HTTP 80.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

ConfiguredTCPNVX device → Syslog TLS collector

Optional · Remote audit logs

Remote syslog over TLS

DM NVX models in 8560H

Use the configured collector port.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

161 (default)UDPSNMP manager → NVX device

Optional · SNMP monitoring

SNMP queries

DM NVX models in 8560H

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

162 (default)UDPNVX device → SNMP manager

Optional · SNMP traps

SNMP notifications

DM NVX models in 8560H

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

3268 (default)TCPNVX device → LDAP global catalog

Optional · Directory integration

Directory global-catalog queries

DM NVX models in 8560H

Additional domain-join services depend on the chosen authentication mode; use the directory profile.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

1812 (default)UDPNVX device → RADIUS server

Optional · RADIUS integration

Authentication service

DM NVX models in 8560H

Select only when this endpoint authentication feature is configured.

Source checked 2026-09-27

Ports and Protocols, printed pp. 3–4

8560H, March 2025

9875UDP

Multicast: 239.255.255.255

NVX transmitter → SAP listeners

Optional · AES67 discovery

AES67 session announcements

NVX/NAX AES67

Source checked 2026-09-27

Port Table, printed p. 3: SAP/SDP
5355TCPName-resolution client → NVX device

Optional · LLMNR

Link-local name resolution

NVX/NAX implementation

8560H explicitly lists TCP; do not substitute generic UDP LLMNR.

Source checked 2026-09-27

Port Table, printed p. 3: LLMNR
3702UDP

Multicast: 239.255.255.250

NVX device / Crestron discovery app → Crestron discovery app / NVX device

Optional · WS-Discovery

Device discovery

DM NVX

Source checked 2026-09-27

Port Table, printed p. 3: WS-Discovery
6205TCPNVX receiver → NVX transmitter

Optional · HDCP

HDCP session key exchange

DM NVX

Source checked 2026-09-27

Port Table, printed p. 3: HDCP Exchange
4570 (default)UDPNVX encoder → NVX decoder

Optional · E10/E20-family transport stream

Transport stream media

DM-NVX-E10/E20 and D10/D20/D200-family configuration covered by Doc. 9219

Use the configured even UDP TS port; 4570 is the documented default. This rule is limited to the named Doc. 9219 model family and must not be copied to 38X endpoints without their own supported mapping.

Source checked 2026-10-22

Configuring Setup and Operational Settings > Stream > Advanced: TS Port is UDP; default 4570; decoder inherits encoded stream port

Crestron Doc. 9219, web configuration guide

Physical, link and configuration requirements

configuration · Optional · Model-specific media profile

Select the exact NVX model and firmware media profile before assigning its transport rule.

DM-NVX-384/384C/385/385C stream selection; no transport assigned from contradictory generic table

The 38X settings identify the TS port but do not resolve the TCP label in Security Reference Guide 8560H. No numeric media allowance is approved for that unresolved model mapping. Obtain the installed model/firmware schedule. A separate row documents UDP TS only for the E10/E20-family configuration explicitly supported by Doc. 9219.

Gotchas & IT Notes

  • ⚠This profile covers documented 38x streaming defaults. Select the model for AES67, PTP, USB and management requirements.
  • ⚠Configure multicast forwarding, QoS and bandwidth for all simultaneous streams. Secure control and content protection are independent features.
  • ⚠Do not approve the 4570 media rule until its transport is confirmed for the deployed firmware; the cited Crestron sources conflict.
  • ⚠The UDP 4570 TS rule is scoped to the Doc. 9219 E10/E20-family profile. The contradictory 38X/generic transport mapping is withdrawn from the operational schedule and retained only as model-selection guidance.