Clearport/PJLink

PJLink

PJLink is JBMIA's standard IP control protocol for projectors and displays. It is not a media transport; it is the common command-and-status layer that lets a controller or monitoring system handle baseline functions such as power, input selection, health/error queries, AV mute/shutter behavior, lamp/light-source/filter runtime, input/resolution metadata, and error status across mixed-vendor display estates. The practical firewall point is simple: PJLink mostly lives on port 4352, with TCP for command sessions and UDP for Class 2 discovery/notification behavior.

Scope: PJLink Class 1/2; select discovery and notifications as required

protocol · Catalog reviewed 2026-09-27

JBMIA PJLink 2.10

Controlindustry-standardlocal lan

Infrastructure Requirements

  1. IP reachability to each endpoint
  2. TCP 4352 for command/query sessions
  3. UDP 4352 for Class 2 search and status-notification functions
  4. password coordination if security is enabled
  5. a pre-registered controller IP if using Class 2 status notification
  6. controller logic that understands Class 1 vs Class 2 behavior, the actual implemented-command list of the target device, and the fact that PJLink authentication is not the same thing as a fully encrypted management session

Network & Physical Requirements

Port / allocationTransportConnection / signal flowFeature and requirementEvidence
4352TCPController → Projector / display

Profile requirement · Core

PJLink commands and status

PJLink Class 1 / Class 2

Source checked 2026-09-27

Section 1-1: TCP 4352 connection cautions

Application Guideline 2.10, 22 March 2024

4352UDP

Multicast: IPv4 subnet broadcast; IPv6 ff02::1

Controller / responding display → Display / searching controller

Optional · Class 2 discovery

Search requests and device replies

PJLink Class 2 search

Search uses local broadcast or link-local IPv6 multicast. The controller and displays listen on UDP 4352 for this exchange.

Source checked 2026-09-27

3.2 Search protocol, pages 10–11

Specification 2.10, 2024-02-29

4352UDPProjector / display → Registered controller

Optional · Class 2 notifications

Spontaneous display status notifications

PJLink Class 2 status notification

Configure the controller IP in the display. The controller listens on UDP 4352.

Source checked 2026-09-27

3.3 Status Notification Protocol, pages 13–14

Specification 2.10, 2024-02-29

Gotchas & IT Notes

  • ⚠Confirm the supported class, commands and authentication mode. A PJLink label does not guarantee every optional Class 2 function.